- Manufacture :
- Mounting Type :
- Actuator Type :
- Operating Pressure :
-
- -13.05 ~ 145 PSI (-0.9 ~ 10 bar) (6)
- 0 ~ 116PSI (0 ~ 8 bar) (9)
- 0 ~ 22 PSI (0 ~ 1.5 bar) (3)
- 14.5 ~ 116 PSI (1 ~ 8 bar) (1)
- 29 ~ 145 PSI (2 ~ 10 bar) (6)
- 30 ~ 116 PSI (2 ~ 8 bar) (10)
- 30 ~ 150 PSI (2 ~ 12 bar) (1)
- 36 ~ 116 PSI (2.5 ~ 8 bar) (2)
- 36 ~ 145 PSI (2.5 ~ 10 bar) (6)
- 44 ~ 116 PSI (3 ~ 8 bar) (9)
- 44 ~ 145 PSI (3 ~ 10 bar) (8)
- 51 ~ 116 PSI (3.5 ~ 8 bar) (1)
- Fluid Type :
- Applied Filters :
63 results
Picture | Mfr Part # | QUANTITY | Inventory | MANUFACTURE | Description | Package | For Use With/Related Products | Mounting Type | Features | Type | Actuator Type | Function | Operating Pressure | Orifice Diameter | Fluid Type | Connection Method | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
GLOBAL STOCKS | |||||||||||||||||
|
VIEW | Crouzet | CONTROL VALVE 3/2 NC CHASSIS MNT | $proddata[$product['id']]['package'] | - | Chassis Mount | - | Control Valve, Momentary | Pedal | 3/2 Normally Closed | 30 ~ 116 PSI (2 ~ 8 bar) | - | Air, Inert Gas | Barbed Connection for Tubing 5/32" (4.00mm) Dia | |||
|
VIEW | Crouzet | CONTROL VALVE 3/2 NO SUB-BASE MT | $proddata[$product['id']]['package'] | - | Sub-Base Mount | - | Control Valve, Momentary | - | 3/2 Normally Open | 44 ~ 116 PSI (3 ~ 8 bar) | - | Air, Inert Gas | - | |||
|
VIEW | Crouzet | CONTROL VALVE 4/2 SUBBASE MNT | $proddata[$product['id']]['package'] | - | Sub-Base Mount | - | Control Valve, Momentary | - | 4/2 | 44 ~ 116 PSI (3 ~ 8 bar) | 0.118" (3.00mm) | Air, Inert Gas | - | |||
|
VIEW | Crouzet | CONTROL VALVE 3/2 NC PANEL MOUNT | $proddata[$product['id']]['package'] | - | Panel Mount | Operating Force 8 ~ 18N | Control Valve, Momentary | Paddle | 3/2 Normally Closed | 30 ~ 116 PSI (2 ~ 8 bar) | 0.106" (2.70mm) | Air, Inert Gas | Push-In Connection for Tubing 5/32" (4.00mm) Dia | |||
|
VIEW | Crouzet | CONTROL VALVE 3/2 NC SUB-BASE MT | $proddata[$product['id']]['package'] | - | Sub-Base Mount | - | Control Valve, Momentary | - | 3/2 Normally Closed | 30 ~ 150 PSI (2 ~ 12 bar) | 0.250" (6.35mm) | Air, Inert Gas | - | |||
|
VIEW | Crouzet | CONTROL VALVE 3/2 NO PANEL MOUNT | $proddata[$product['id']]['package'] | - | Panel Mount | - | Control Valve, Momentary | - | 3/2 Normally Open | 0 ~ 116PSI (0 ~ 8 bar) | 0.079" (2.00mm) | Air, Inert Gas | Push-In Connection for Tubing 5/32" (4.00mm) Dia | |||
|
VIEW | Crouzet | CONTROL VALVE 3/2 NO PANEL MOUNT | $proddata[$product['id']]['package'] | - | Panel Mount | - | Control Valve, Momentary | - | 3/2 Normally Open | 0 ~ 116PSI (0 ~ 8 bar) | 0.079" (2.00mm) | Air, Inert Gas | Push-In Connection for Tubing 5/32" (4.00mm) Dia | |||
|
VIEW | Festo Corporation | VALVE | $proddata[$product['id']]['package'] | Control Valve | Chassis Mount | - | Control Valve, Momentary | - | - | 0 ~ 116PSI (0 ~ 8 bar) | - | AIR | Threaded | |||
|
VIEW | Festo Corporation | VALVE | $proddata[$product['id']]['package'] | Control Valve | Chassis Mount | - | Control Valve, Momentary | - | - | 36 ~ 116 PSI (2.5 ~ 8 bar) | - | - | Threaded | |||
|
VIEW | Festo Corporation | VALVE | $proddata[$product['id']]['package'] | Control Valve | Chassis Mount | - | Control Valve, Momentary | - | - | 14.5 ~ 116 PSI (1 ~ 8 bar) | - | AIR | Threaded | |||
|
VIEW | Festo Corporation | VALVE | $proddata[$product['id']]['package'] | Control Valve | Chassis Mount | - | Control Valve, Momentary | - | - | 36 ~ 116 PSI (2.5 ~ 8 bar) | - | - | Threaded | |||
|
VIEW | Crouzet | CONTROL VALVE 4/2 SUBBASE MNT | $proddata[$product['id']]['package'] | - | Sub-Base Mount | - | Control Valve, Momentary | - | 4/2 | 51 ~ 116 PSI (3.5 ~ 8 bar) | - | Air, Inert Gas | - | |||
|
VIEW | Festo Corporation | BASIC VALVE | $proddata[$product['id']]['package'] | Control Valve | Chassis Mount | - | Control Valve, Momentary | - | 5/3 Normally Closed | -13.05 ~ 145 PSI (-0.9 ~ 10 bar) | - | AIR | Threaded G3/4" | |||
|
VIEW | Festo Corporation | BASIC VALVE | $proddata[$product['id']]['package'] | Control Valve | Chassis Mount | - | Control Valve, Momentary | - | 5/3 | -13.05 ~ 145 PSI (-0.9 ~ 10 bar) | - | AIR | Threaded G3/4" | |||
|
VIEW | Festo Corporation | BASIC VALVE | $proddata[$product['id']]['package'] | Control Valve | Chassis Mount | - | Control Valve, Momentary | - | 5/3 | -13.05 ~ 145 PSI (-0.9 ~ 10 bar) | - | AIR | Threaded G3/4" | |||
|
VIEW | Festo Corporation | BASIC VALVE | $proddata[$product['id']]['package'] | Control Valve | Chassis Mount | - | Control Valve, Momentary | - | 5/3 | 36 ~ 145 PSI (2.5 ~ 10 bar) | - | AIR | Threaded G3/4" | |||
|
VIEW | Festo Corporation | BASIC VALVE | $proddata[$product['id']]['package'] | Control Valve | Chassis Mount | - | Control Valve, Momentary | - | 5/3 | 36 ~ 145 PSI (2.5 ~ 10 bar) | - | AIR | Threaded G3/4" | |||
|
VIEW | Festo Corporation | BASIC VALVE | $proddata[$product['id']]['package'] | Control Valve | Chassis Mount | - | Control Valve, Momentary | - | 5/3 Normally Closed | 36 ~ 145 PSI (2.5 ~ 10 bar) | - | AIR | Threaded G3/4" | |||
|
VIEW | Crouzet | CONTROL VALVE 3/2 NC PANEL MOUNT | $proddata[$product['id']]['package'] | - | Panel Mount | Operating Force 8 ~ 18N | Control Valve, Momentary | Paddle | 3/2 Normally Closed | 30 ~ 116 PSI (2 ~ 8 bar) | 0.106" (2.70mm) | Air, Inert Gas | Push-In Connection for Tubing 5/32" (4.00mm) Dia | |||
|
VIEW | Crouzet | CONTROL VALVE 3/2 NO SUB-BASE MT | $proddata[$product['id']]['package'] | - | Sub-Base Mount | - | Control Valve, Momentary | - | 3/2 Normally Open | 44 ~ 116 PSI (3 ~ 8 bar) | 0.118" (3.00mm) | Air, Inert Gas | - | |||
|
3
In-stock
|
Crouzet | CONTROL VALVE 3/2 NC ROD MOUNT | $proddata[$product['id']]['package'] | - | Rod Mount | Operating Force 8 ~ 18N | Control Valve, Momentary | Pushbutton | 3/2 Normally Closed | 30 ~ 116 PSI (2 ~ 8 bar) | 0.106" (2.70mm) | Air, Inert Gas | Push-In Connection for Tubing 5/32" (4.00mm) Dia | |||
|
16
In-stock
|
Crouzet | CONTROL VALVE 3/2 NO ROD MOUNT | $proddata[$product['id']]['package'] | - | Rod Mount | Operating Force 8 ~ 18N | Control Valve, Momentary | Pushbutton | 3/2 Normally Open | 30 ~ 116 PSI (2 ~ 8 bar) | 0.106" (2.70mm) | Air, Inert Gas | Push-In Connection for Tubing 5/32" (4.00mm) Dia | |||
|
VIEW | Festo Corporation | VACUUM VALVE | $proddata[$product['id']]['package'] | Control Valve | Chassis Mount | Supply Voltage 24VDC | Control Valve, Momentary | - | 2 x 2/2 Normally Closed | 0 ~ 22 PSI (0 ~ 1.5 bar) | - | AIR | Connector | |||
|
VIEW | Festo Corporation | VACUUM VALVE | $proddata[$product['id']]['package'] | Control Valve | Chassis Mount | Supply Voltage 24VDC | Control Valve, Momentary | - | 2 x 2/2 Normally Closed | 0 ~ 22 PSI (0 ~ 1.5 bar) | - | AIR | Connector | |||
|
VIEW | Crouzet | CONTROL VALVE 3/2 NO PANEL MOUNT | $proddata[$product['id']]['package'] | - | Panel Mount | - | Control Valve, Momentary | - | 3/2 Normally Open | 0 ~ 116PSI (0 ~ 8 bar) | 0.079" (2.00mm) | Air, Inert Gas | Threaded 1/8" BSP | |||
|
VIEW | Festo Corporation | VACUUM VALVE | $proddata[$product['id']]['package'] | Control Valve | Chassis Mount | Supply Voltage 24VDC | Control Valve, Momentary | - | 2 x 2/2 Normally Closed | 0 ~ 22 PSI (0 ~ 1.5 bar) | - | AIR | Connector | |||
|
VIEW | Crouzet | CONTROL VALVE 3/2 NO PANEL MOUNT | $proddata[$product['id']]['package'] | - | Panel Mount | - | Control Valve, Momentary | - | 3/2 Normally Open | 0 ~ 116PSI (0 ~ 8 bar) | 0.079" (2.00mm) | Air, Inert Gas | Push-In Connection for Tubing 5/32" (4.00mm) Dia | |||
|
VIEW | Festo Corporation | BASIC VALVE | $proddata[$product['id']]['package'] | Control Valve | Sub-Base Mount | - | Control Valve, Momentary | - | 5/3 | 44 ~ 145 PSI (3 ~ 10 bar) | - | AIR | Threaded G1/4" | |||
|
VIEW | Festo Corporation | BASIC VALVE | $proddata[$product['id']]['package'] | Control Valve | Sub-Base Mount | - | Control Valve, Momentary | - | 5/3 | 44 ~ 145 PSI (3 ~ 10 bar) | - | AIR | Threaded G1/4" | |||
|
VIEW | Festo Corporation | BASIC VALVE | $proddata[$product['id']]['package'] | Control Valve | Sub-Base Mount | - | Control Valve, Momentary | - | 5/3 Normally Closed | 44 ~ 145 PSI (3 ~ 10 bar) | - | AIR | Threaded G1/4" |